    The Thumper connects to a pressurized water-filled line and uses water flow to create a controlled mechanical pulse inside the pipe. That pulse travels through the line, allowing technicians to acoustically trace the path of underground plastic or PVC pipe from the surface.
    Price: $645.00

    Videos

    Details

    The Thumper is designed to generate a powerful, repeatable mechanical pulse in water filled lines for acoustic pipe tracing and location.
    • Generates a strong, consistent mechanical pulse
    • Simple connection and operation
    • No electronics or batteries required
    • Built for field durability and long service life
    • Compatible with standard water sources
    • Helps improve trace accuracy and locating efficiency

    BEFORE YOU BEGIN

    • Ensure you have the proper fittings and a pressurized water source.

    • Inspect the Thumper for any debris and ensure the screen is clean.

    CONNECTION & START-UP

    • Attach the Thumper to a hose bib or fitting.

    • Tighten the adjustment screw only until slight pressure is felt against the spring. Do not over-tighten or fully compress the spring.

    • The piston only needs to be slightly unseated to allow water flow.

    • Turn the water on and confirm water flows from the exit port.

    • A short hose can be attached to the exit port to divert water away.

    ADJUSTING THE PULSE

    • Slowly back the adjustment screw out until the Thumper begins to vibrate or pulse.

    • A range of pulse frequencies may be ava lab e depending on water pressure.

    • Hold the adjustment screw and tighten the lock nut to secure the setting.

    LOCATING THE LINE

    • The Thumper should continue running during acoustic locating.

    • If it stops, restart and adjust to a slightly different pitch or frequency.

    • Move along the route and listen for the strongest signal to trace the line.

    SHUTDOWN & STORAGE

    • When done, turn the water off and remove the Thumper.

    • For storage, back the adjustment screw out until the spring sits loosely inside the thumper.

    • Store in a clean, dry place.