The Thumper is designed to generate a powerful, repeatable mechanical pulse in water filled lines for acoustic pipe tracing and location.- Generates a strong, consistent mechanical pulse
- Simple connection and operation
- No electronics or batteries required
- Built for field durability and long service life
- Compatible with standard water sources
- Helps improve trace accuracy and locating efficiency
BEFORE YOU BEGIN
• Ensure you have the proper fittings and a pressurized
water source.
• Inspect the Thumper for any debris and ensure the screen
is clean.
CONNECTION & START-UP
• Attach the Thumper to a hose bib or fitting.
• Tighten the adjustment screw only until slight pressure is
felt against the spring. Do not over-tighten or fully compress the spring.
• The piston only needs to be slightly unseated to allow
water flow.
• Turn the water on and confirm water flows from the exit
port.
• A short hose can be attached to the exit port to divert
water away.
ADJUSTING THE PULSE
• Slowly back the adjustment screw out until the Thumper begins
to vibrate or pulse.
• A range of pulse frequencies may be ava lab e depending on
water pressure.
• Hold the adjustment screw and tighten the lock nut to secure
the setting.
LOCATING THE LINE
• The Thumper should continue running during acoustic locating.
• If it stops, restart and adjust to a slightly different pitch
or frequency.
• Move along the route and listen for the strongest signal to
trace the line.
SHUTDOWN & STORAGE
• When done, turn the water off and remove the Thumper.
• For storage, back the adjustment screw out until the spring
sits loosely inside the thumper.
• Store in a clean, dry place.
Leave a Review